Technical specifications:
| High-end Color Ultrasonic Diagnostic Apparatus | |
| 1: | Summary of main specifications and system |
| 1.1 | Trolley type all digital color Doppler ultrasonic mainframe |
| 1.2 | Ultrasonic host operating system: Windows operating system |
|
1.3 |
Applications:
Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal |
|
1.4 |
Probes:
Convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, Cardiac probe,4D Volume probe |
|
1.5 |
Applications and report:
Abdominal,OB,GYN,Cardiac,Urinary,Small Parts,Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc. |
| ☆1.6 | carotid artery intima measurement thickness(IMT) |
| ☆1.7 | Automatic spectral envelope measurement |
| 1.8 | Full digital transmission and reception of beam synthesizer |
| 1.9 | Color Doppler imaging(C) |
| 1.10 | Pulse Doppler Imaging(PW) |
| 1.12 | Continuous wave Doppler imaging(CW) |
| ☆1.13 | B/C/D Real-time three synchronous imaging |
| ☆1.14 | Power Doppler imaging(PDI) |
| ☆1.15 | Direct power Doppler imaging(DPDI) |
| 1.16 | M mode imaging |
| ☆1.17 | Anatomic M mode imaging |
| ☆1.18 | Color Doppler M mode imaging |
| ☆1.20 | Tissue Doppler imaging(TDI) |
| ☆1.21 | Strain rate imaging (SRI) |
| 1.22 | Tissue harmonic imaging(THI) |
| 1.23 | Fusion harmonic imaging(FHI) |
| 1.24 | Speckle Reduce imaging(SRI) |
| ☆1.26 | Deflection imaging |
| ☆1.27 | Trapezoidal imaging |
| 1.28 | Adaptive velocity optimization |
| ☆1.29 | Free hand 3D |
| 1.30 | Real time 3D imaging(3D/4D) |
| 1.31 | DICOM3.0 |
| 1.32 | Monitor:21.5 inch ,high definition ultrasonic display |
| 1.33 | 13.3 inch touch screen |
| 1.34 | Physical clipboard: save the image on the left side of the screen, which can be directly saved or deleted. |
| 1.35 | The system has the function of on-the-spot upgrade |
|
1.36 |
Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation. |
| 1.37 | Probe interface: 4 |
| 1.38 | Chinese and English System, Chinese and English input, optional |
| 1.39 | Depth:≥360mm; |
| 1.40 | Extended imaging |
| 2: | Probes |
| 2.1
Convex probe |
Fundamental Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz,
Harmonic Frequency:4.0MHz/4.6MHz/5.0MHz, |
| 2.2
Linear probe |
Fundamental Frequency:
4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz, Harmonic Frequency:8.0MHz/9.2MHz/10.0MHz, |
| 2.3
Trans-vagin al probe |
Fundamental Frequency:
3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
| 2.4 | Fundamental Frequency: |
| Micro-conv
ex probe |
3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz,
Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
| 2.5
Cardiac probe |
Fundamental Frequency:
1.7MHz/1.9MHz/2. 1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz, Harmonic Frequency: 3.4MHz/3.8MHz/4.2MHz, |
| 2.6
4D Volume probe |
Fundamental Frequency:
2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz, Harmonic Frequency: 4.0MHz/5.0MHz/6.0MHz, |
| 2.7:
Transrectal probe |
Fundamental frequency:
3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz Harmonic frequency: 6.0MHz/7.0MHz/8.0MHz |
| 3: | 2D imaging mode |
| 3.1 | Gain:0-100 ,Step 2 adjustable |
| 3.2 | TGC: 8 segment adjustable |
| 3.3 | Maximum focus point:≥7, which can be moved throughout the whole process. |
| 3.4 | Speckle reduction:0-5 ,5 level |
| 3.5 | Space Synthesis:0-2 ,2 level(Liner probe: 3 level , cardiac probe:0) |
| 3.6 | Dynamic:30-180 ,35 level ,step 5 adjustable |
| 3.7 | Line density:low 、middle 、high ,3 level |
| 3.8 | Frame correlation:0-4,4 level |
| 3.9 | Noise reduction:0-5 ,5 level |
| 3.10 | Edge Enhancement:0-5 ,5 level |
| 3.11 | Sound power:2-10, 9 level |
| 3.12 | Grey scale:0-67, 67 level |
| 3.13 | False color:0-67 ,67 level |
| 3.14 | Image style: Soft-Comparison ,2 level |
| The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted | |
| 4: | Color Doppler imaging mode |
| 4.1 | Blood gain:0-100 ,Step 2 |
| 4.2 | Parameter display:Velocity、Variance |
| 4.3 | B-Restrain(B/W restrain):0-7, 7 level |
| 4.4 | Speed Through:0-8, 8 level |
| 4.5 | Sampling number:6-24, 7 level |
| 4.6 | Blood flow preferred:0-8, 8 level |
| 4.7 | Filtering: 1-6, 6 level |
| 4.8 | Sound power:2-6, 4 level |
| 4.9 | Noise reduction:0-4, 4 level |
| 4.10 | Smooth treatment:0-4 , 4 level |
| 4.11 | Frame correlation:0-6 , 6 level |
| 4.12 | Chromatography(Blood flow graph):0-37 , 37 level |
| 4.13 | Line density:Low-Middle-High , 3 level |
| 4.14 | Frequency:4 level adjustable |
|
4.15 |
Velocity:Minimum 0.4K ,Maximum 40.5K
Convex probe:0.4K-4.3K-38.5K Linear probe:0.4K-14.7K-39.0K Trans-vaginal probe:0.4K-7.8K-39.7K Volume probe:0.4K-4.2K-34.8K Micro-convex probe:0.4K-10.3K-40.5K cardiac probe:0.4K-7.8K-39.7K |
| PS:The frequency of the probe changes and the frequency value changes | |
| PS:Frame rate changes with speed | |
| 5: | Pulse wave Doppler(PW) |
| 1 | Gain:0-100 ,Step 2 |
|
5.2 |
Spectrum envelope function: real time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR and so on. Can wake up or close |
| 5.3 | Sample volume:0.5mm~30mm |
| 5.4 | Blood angel:-75—75 degree ,Step 5 |
| 5.5 | False color:0-67 , 67 level |
| 5.6 | Dynamic range:20-40 , 4 level |
| 5.7 | Filter:0-9, 9 level |
| 5.8 | Smooth treatment: 1-4 , 4 level |
| 5.9 | Sound power:2-5 , 4 level |
| 5.10 | Volume:0-100, 10 level ,Step 10 |
| 5.11 | Audio filtering:0-4 , 4 level |
| 5.12 | Base line:-1.0~ 1.0, |
| 5.13 | Grey map:0-67 , 67 level |
| 5.14 | Scan velocity: 100-500, 6 level |
|
5.15 |
PRF:Minimum 0.5K ,Maximum 87.5K
Convex probe:0.5K-4.3K-63.3K Linear probe:0.5K-14.5K-78.4K Trans-vaginal probe:0.5K-8. 1K-78.4K Volume probe:0.5K-4.2K-53.8K Micro-convex probe:0.5K-10.3K-81. 1K cardiac probe:0.5K-4.3K-87.5K |
| 5.16 | Frequency:4 level |
| PS:The frequency of the probe changes and the PRF value changes | |
| PS:The frequency of the probe changes and the frequency value changes | |
| 6: | Continuous Wave Doppler(CW) |
| 6.1 | Support probe:Cardiac probe |
| 6.2 | Adjustment of B mode parameters is switchable |
| 6.3 | Gain:0-100 ,Step 2 |
| 6.4 | Sampling line position is adjustable |
| 6.5 | PRF:0.9K~36. 1K |
| 6.6 | Baseline:-1.0~ 1.0 |
| 6.7 | Blood angel:-75~75 degree |
| 6.8 | Grey map:0-67 |
| 6.9 | Scan velocity: 100-300 |
| 6.10 | False color:0-67 |
| 6.11 | Dynamic range:20-40 |
| 6.12 | Filtering:0-9 ,9 level |
| 6.13 | Smooth treatment: 1-4 |
| 6.14 | Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz ,4 level adjustable |
| 6.15 | Sound power:2-5 |
| 6.16 | Volume:0-100 |
| 6.17 | Audio Filtering:0-4 |
| ☆7: | Anatomical M imaging |
| 7.1 | Support probe:Convex probe, Linear probe,Cardiac probe |
| 7.2 | Adjustment of B mode parameters is switchable |
| 7.3 | Gain:0-100 ,Step 2 |
| 7.4 | M Sampling line angel is adjustable |
| 7.5 | M Sampling line length is adjustable |
| 7.6 | Sampling line:3 ,Can be displayed or hidden separately |
| ☆8: | Blood flow M model(MC) |
| 8.1 | Adjustment of B mode parameters is switchable |
| 8.2 | Gain:0-100 ,Step2 |
| 8.3 | MC Sampling line angel is adjustable |
| 8.4 | MC Sampling line length is adjustable |
| 8.5 | Frequency:4 level |
| 8.6 | Sampling number:6-24 |
| 8.7 | Speed through:0-8, 8 level |
| 8.8 | Scan velocity: 150-500 |
| 8.9 | Frame correlation:0-6, 6 level |
| 8.10 | Filtering: 1-6 ,6 level |
| 8.11 | Blood flow preferred:0-8 ,8 level |
| 8.12 | Smooth treatment:0-4,4 level |
| 8.13 | Map:0-37, 37 level |
| ☆9: | Elastography |
| 9.1 | Adjustment of B mode parameters is switchable |
| 9.2 | Gain:0-100 ,Step 2 |
| 9.3 | B/E ,Double real-time display on the same screen |
| 9.4 | Probe displacement curve display:Up/Down |
| 9.5 | Pressure indicator bar display |
| 9.6 | Frequency: 8-9 level ,Adjustable;According to the probe display |
| 9.7 | Noise reduction:0-2, 2 level |
| 9.8 | Frame correlation:0-3, 3 level |
| 9.9 | Comparison:0-13, 13 level |
| 9.10 | False color:0-3 , 3 level |
| 9.11 | Don’t support cardiac probe |
| ☆10: | Tissue Doppler imaging(TDI) |
| 10.1 | Support probe: Cardiac probe |
| 10.2 | Adjustment of B mode parameters is switchable |
| 10.3 | Gain:0-100 ,step 2 |
| 10.4 | ROI area adjustable |
| 10.5 | Sampling number:6-24 |
| 10.6 | Velocity:0.4K-8.0K |
| 10.7 | Frame correlation:0-6 ,6 level |
| 10.8 | Tissue preferred:0-7, 7 level |
| 10.9 | Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz |
| 10.10 | Support color reversal |
| ☆11: | Strain rate imaging |
| 11.1 | Support probe: Cardiac probe |
| 11.2 | Adjustment of B mode parameters is switchable |
| 11.3 | ROI area adjustable |
| 11.4 | Gain:0-100 ,Step 2 |
| 11.5 | Sampling number:6-24 ,6 level |
| 11.6 | Axial average: 1-4 , 4 level |
| 11.7 | Velocity:0.4K-8K |
| 11.8 | Frame correlation:0-6 , 6 level |
| 11.9 | Tissue optimization:0-7 ,7 level |
| ☆12: | Panoramic imaging |
| 12.1 | Support probe:Linear probe |
| 12.2 | Speckle Reduction:0-5, 5 level |
| ☆13: | Deflection imaging |
| 13.1 | Support probe:Linear probe |
| 13.2 | Adjustment of B mode parameters is switchable |
| 13.3 | Deflection angel: 8 level |
| 13.4 | Speckle reduction:0-5, 5 level |
| 13.5 | Dynamic rate:30-180 ,Step 5 |
| 13.6 | Line density:low-middle-high ,3 level |
| 13.7 | Frame Correlation:0-4 , 4 level |
| 13.8 | False color:0-67, 67 level |
| 13.9 | Image style: Soft-Comparison ,2 level |
| 13.10 | Noise reduction:0-5, 5 level |
| 13.11 | Edge Enhancement:0-5 ,5 level |
| 13.12 | Sound power:2-10 ,8 level |
| 13.13 | Grey map:0-67 ,67 level |
| ☆14: | Trapezoidal imaging |
| 14.1 | Probe support:linear probe |
| 14.2 | Adjustment of B mode parameters is switchable |
| 14.3 | Deflection angel: 8 level |
| 14.4 | Speckle reduction: 0-5, 5 level |
| 14.5 | Dynamic rate: 30-180 ,Step 5 |
| 14.6 | Line density: low-middle-high ,3 level |
| 14.7 | Frame Correlation: 0-4 , 4 level |
| 14.8 | False color: 0-67, 67 level |
| 14.9 | Image style: Soft-Comparison ,2 level |
| 14.10 | Noise reduction: 0-5, 5 level |
| 14.11 | Edge Enhancement: 0-5 ,5 level |
| 14.12 | Sound power: 2-10 ,8 level |
| 14.13 | Grey map: 0-67 , 67 level |
| 14.14 | Space Synthesis:0-2, 2 level |
| ☆15 | Freehand 3D imaging |
| 15.1 | Support probe:convex probe, linear probe |
| 15.2 | Display model: 4 pictures |
| 15.3 | Image Rotation X/Y/Z Axis |
| 15.4 | Multi-slice Visibility |
| 16 | Real-time 4D imaging |
| 16.1 | Support probe: 4D volume probe |
| 16.2 | Adjustment of B mode parameters is switchable |
| 16.3 | Gain:0-100 ,Step 2 |
| 16.4 | Display model:one image 、two images 、four images |
| 16.5 | Image Rotation:X/Y/Z Axis |
| 16.6 | Multi-slice Visibility |
| 16.7 | Light&Shade inversion |
| 16.8 | Smooth:0-4, 4 level |
| 16.9 | Threshold level:0-129, Step 3 |
| 16.10 | Transparency: 1-509 ,Step 10 |
| 16.11 | Render type:4 kinds ,Surface 、maximum 、minimum 、perspective |
| 17: | Extended Imaging |
| 17.1 | Gain:0-100 ,Step 2 |
| 17.2 | TGC: 8 segment adjustable |
| 17.3 | Maximum focus point:≥7, which can be moved throughout the whole process. |
| 17.4 | Speckle reduction:0-5 ,5 level |
| 17.5 | Space Compound:0-2 ,2 level(Linear probe: 3 level ,don’t support cardiac probe) |
| 17.6 | Dynamic range:30-180 ,35 level ,Step 5 |
| 17.7 | Line density:Low 、Middle 、High ,3 level |
| 17.8 | Frame correlation:0-4,4 level |
| 17.9 | Noise reduction:0-5 ,5 level |
| 17.10 | Edge enhancement:0-5 ,5 level |
| 17.11 | Sound power:2-10, 9 level |
| 17.12 | Grey map:0-67, 67 level |
| 17.13 | False color:0-67 ,67 level |
| 17.14 | Image style: Soft-Comparison ,2 level |
|
17.15 |
Extended level: Maximum 72 level
Convex probe:9 level Trans-vaginal probe:72 level Micro-convex probe:29 level Cardiac probe:40 level 4D Volume probe: 17 level |
| PS:The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted | |
| PS: When the probe scan range reaches the maximum, the space synthesized is 0. | |
| 18: | Measurement and analysis function: |
| 18.1 | General measurement: Distance, area, ellipse, cross line, angle, distance ratio, volume, Volume (ellipse), area ratio, diameter, joint angle |
|
18.2 |
Cardiac:Automatic spectrum envelope 、LV、Main Pulmonary artery diameter、RVEDd 、RVEDs、
LVM、LAV、HR、MVF、AO、AR、LVOT、TVF、Pulmonic valve、Pulmonary vein、RV、Doppler fetal heart sound、LVET、LVM、LVMI 、AV |
| 18.3 | Vascular: carotid intima (IMT), length stenosis ratio, area stenosis ratio, IMT (back wall), IMT (front wall) |
| 18.4 | OB:Fetal routine 、AFI 、TW 、GS 、CRl 、OFD 、HL 、ulna 、NT 、Fibula 、Nbonel、Radial 、Tibia |
| 18.5 | GYN:uterus、cervix、corpus uteri/cervix uterus、left ovarian vein、right ovarian vein、dominant follicle、 intima thickness |
| 18.6 | Urology: prostate、residual urine、left kidney、right kidney、left suprarenal vein、right suprarenal、left testis 、right testis 、left seminal vesicle 、right seminal vesicle |
| 18.7 | Abdomen:liver 、CHD、partal vein diameter、cholecyst 、CBD、pancreas 、spleen、Internal diameter of abdominal aorta 、kidney |
| 18.8 | Small parts:Thyroid |
| 18.9 | Software package:Measurement package 、Software package 、Medical records management software package |
| 19: | Graphic and text management system |
| 19.1 | Host build in 2 hard disk (SSD 128GB+HDD 1TB), Start fast and stable |
| 19.2 | Movie playback:≥1200 frames |
| 19.3 | Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on. |
| 19.4 | Type of report is 16 |
| 19.5 | One key fast report graphic and text management |
| 20: | Interface |
| 20.1 | USB interface: 4 |
| 20.2 | HDMI interface: 1 |
| 20.3 | RJ-45 interface: 1 |
| 20.4 | Grounding wire interface: 1 |
| 20.5 | DVD RW: 1 |
| 21: | Configuration |
| 21.1 | Trolley type full digital color Doppler ultrasound diagnostic system main unit |
| 21.2 | Probe options: convex, linear , Trans-vaginal , phased array, micro-convex, 4D volume and trans-rectal |
| 21.3 | ≥13 quick adjusting knobs |
| 22: | Technology, after-sales service and other requirements |
| 22.1 | Two years warranty for both main unit and probes |