    Advanced automated adaptive assisted wide-range ventilation system with electronic microprocessor controlled by volume and pressure to fit for all types of patients from Neonates, Pediatrics to Adults.
    15.6" TFT touch screen (18.5" optional), the screen supports 360 degree rotation left and right.
    Both invasive and non-invasive modes make the unit wide applications.
    Integrated self-check system with leak check and system tightness to secure the ventilation result(POST: Power On self test).
    Automatic leakage compensation by the unit provides is giving to optimize respirator settings.
    Two Lithium batteries guarantee the unit usage up to 6 hours.
    Manual settable Inspiratory pause from 0-60%.
    The unit is with automatic triggers adjustment both on flow trigger and pressure trigger.
    The unit is with measurement of volumetric capnography of CO2 ( ETCO2 measurement function optional)
    AMV mode can minimize the work of breathing under the target minute ventilation.
    Feature

Specifications:

Physical Specifications

Specifications
Dimensions(H*L*W) 576mm×404mm×284mm(mainunit)

1341mm×595mm×463.5mm (with trolley)

Weight Approximately 15.0kg(main unit), Approximately < 35 kg (with trolley)

 

Ventilation Specifications

 

Specifications
Patient Type

 

Adult, Pediatric, Neonatal

 

Invasive Ventilation Mode

 

• VCV (Volume Controlled – Assist Control Ventilation)

• PCV (Pressure Controlled – Assist Control Ventilation)

• PRVC (Pressure Regulated Volume Control-Assist Control Ventilation)

• V-SIMV (Volume Controlled – Synchronized Intermittent Mandatory Ventilation)

• P-SIMV (Pressure Controlled – Synchronized Intermittent Mandatory Ventilation)

• PRVC-SIMV (Pressure Regulated Volume Control – Synchronized Intermittent

Mandatory Ventilation)

• CPAP/PSV (Continuous Positive Airway Pressure/Pressure support ventilation)

• CPAP-VG (Continuous Positive Airway Pressure-Volume Guarantee)

• APRV (Pressure Controlled – Airway Pressure Release Ventilation)

• Dual PAP (Pressure Controlled-Duo Positive Airway Pressure)

 

Optional:

 

• AMV (Adaptive minute ventilation)

• nCPAP (NasalContinuous Positive Airway Pressure)

Non-invasive Ventilation Mode

 

• PRVC (Pressure Regulated Volume Control-Assist Control Ventilation)

• P-SIMV (Pressure Controlled – Synchronized Intermittent Mandatory Ventilation)

• PRVC-SIMV (Pressure Regulated Volume Control – Synchronized Intermittent

Mandatory Ventilation)

• Dual PAP (Pressure Controlled-Duo Positive Airway Pressure)

• APRV (Pressure Controlled – Airway Pressure Release Ventilation)

• CPAP/PSV (Continuous Positive Airway Pressure/Pressure support ventilation)

• CPAP-VG (Continuous Positive Airway Pressure-Volume Guarantee)

• nCPAP (Neonatal continuous positive airway pressure ventilation mode)

• Apnea Ventilation

• PCV (Pressure Controlled – Assist Control Ventilation)

 

Oxygen therapy • HFNC (High Flow Nasal Cannula oxygen therapy)

 

Controlled Parameters

Parameter Range Unit
VT (Tidal Volume) 100 to 2000 (Adult) , 20 to 300 (Pediatric) Optional:2 to 200 (Neonatal) mL

mL

Pinsp 3 to 100 cmH2O
Phigh Dual PAP: 3 to 80 , APRV: 3 to 100 cmH2O
Plow 0 to 50 cmH2O
Psupp 0 to 80 cmH2O
PEEP 0 to 50 cmH2O
FiO2 21 to 100 %
Rate 1 to 100 bpm
I:E 4:1 to 1:10 /
Tinsp 0.1 to 12.0 s
Sign interval 1 to 200 s
Tpause OFF,1 to 60 %
Thigh 0.1 to 30.0 s
Tlow 0.2 to 60.0 s
Trigger Pressure: OFF,-0.5 to -20

Flow: OFF,0.1 to 20

cmH2O L/min
Tslope 0.00 to 2.00 s
Exp% Auto,5 to 95 %

 

 

Controlled Parameters(O2 Therapy)

Parameter Range Unit
Continuous Flow 2.0 to 80.0(Adult),2.0 to 50.0(Pediatric)

2.0 to 30.0(Neonatal)

L/min
O2 Concentration 21 to 100 %
Pmax 10 to 95 cmH2O

 

Parameter monitoring accuracy

Parameter

 

Range Unit
Ppeak 0 to 99 cmH2O
Pmean 0 to 99 cmH2O
Pplat 0 to 99 cmH2O
PEEP 0 to 99 cmH2O
P0.1 -105 to 5 cmH2O
VTe mand 0 to 4000 mL
VTe spon 0 to 4000 mL
VTi mand 0 to 4000 mL
VTi spon 0 to 4000 mL
MVe 0 to 99 L/min
MVe spon 0 to 99 L/min
MVi mand 0 to 99 L/min
MVi spon 0 to 99 L/min
Tinsp 0 to 25 s
Texp 0 to 25 s
PIF 0 to 196 L/min
PEF -196 to 0 L/min
Vt Leak 0 to 5000 mL
Rtotal 0 to 150 bpm
RR spon 0 to 150 bpm
FiO2 21 to 100 Vol.%
Rlung 3 to 300 cmH2O/L/s
Cdynamic 0.5 to 200 mL/cmH2O
RSB 0 to 9999 bpm/min/L
PTP 0 to 10 cmH2O ·s

 

Monitored Parameters

Numeric
Ppeak VTe FiO2
Pplat VTe spon Rlung
Pmean VTi Cdynamic
PEEP VTi spon PTP
PIF Rtotal EtCO2
PEF RR spon FiCO2
MVe I:E awRR
MVe spon Tinsp SpO2
MVi Texp PR
MVi spon
Real Time Graphics
Pressure-time Waveform Flow-Pressure Loop
Flow-time Waveform Volume-Flow Loop
Volume-time Waveform Pressure-Volume Loop
EtCO2-time Waveform
SpO2-time Waveform

 

Alarm

Parameters
Pressure high/low SpO2 high/low Hose disconnected
VTi high/low PR high/low Airway obstructed
O2 supply failure Battery low AMV: cannot meet target
PEEP high/low System down/fan broken Paw sensor malfunction
Rtotal high/low Battery disconnect No Pressure sensor
Airway Obstructed AC disconnect No O2 sensor
FiO2 high/low Power down CO2 communication stopped
EtCO2 high/low Vt Limited CO2 sample-line occluded
awRR high/low Pressure limited SpO2 Sensor off
Apnea Tube leak

 

O2 Therapy

Specifications O2 % Flow
Controlled Parameters 21-100% (Increments of 1%) 2.0-80.0(Adult), 2.0-50.0(Pediatric), 2.0-30.0(Neonatal)
Controlled Accuracy ± (3vol.% +1% of Setting) ±(2L/min+10% of Setting) (BTPS)

 

Trend & Record

Specifications
Type Tabular, Graphic
Length 120 hours
Content Monitor Parameters
Event Log 500

 

 

Environmental Specifications

Specifications Operating Storage and transport
Temperature 5-40℃ -20 to +60℃(O2 Sensor: -20 to +50℃)
Relative Humidity 10-95% 10-95%
Barometric Pressure  62-106kPa 50-106kPa

 

Gas Supply

Specifications
Gas Supply  Medical-grade Oxygen
Pipe Connector NIST or DISS
Gas Supply Pressure 280-600kPa (0-100kPa for low pressure connector)

 

Low-pressure oxygen inlet

Specifications
Pressure range Less than 100kPa
Maximum flow 15 L/min (STPD)
Connector CPC quick connector

 

Power & Battery Backup

Specifications
External AC Power Supply Input Voltage 100-240V
Input Frequency 50/60Hz
Overcurrent protection 10 ± 5%A
Fuse T10AH/250V
Number of Batteries Two
Battery Type Build-in Lithium-ion Battery, 14.8VDC, 5200mAh
Battery Running Time 6 hours (2 Qty Battery)

 

Communication interface

Specifications
Communication Interface RJ45, RS232, USB, Nurse call, CO2  Module Connector, SpO2  Module Connector

 

Value Added Functions

Specifications

O2 therapy                 Screen-lock

Nebulization               Sigh

Manual Breath            SPO2

Inspiratory Hold           CO2

Expiratory Hold             RSB

PEEPi                              Compliance

P0.1                            Calibrate

ATC                          O2 suction

Related Products

SMT-30F Medical Ventilator

High-flow nasal cannula SMT-30F is a High Flow Nasal Cannula Oxygen Therapy Device capable of delivering up to 100% humidified and heated oxygen at a flow rate of up to 80L/min, it delivers a mixed oxygen with an easy controlled temperature and humidity. The oxygen supply system provides a great solution of airway management and oxygenation improvement.