Specifications:

 

Mode of Ventilation

VCV,PCV,SIMV-VCV,SIMV-PCV,CPAP/PSV,APRV,BIPAP

VS(Optional),NIV(Optional),

PRVC(PCV-VG),SIMV-PRVC(SIMV-PCV-VG)(Optional)

Ventilation Settings

Tidal Volume          20~2500ml

Oxygen Concentration  21~100%

Frequency            1~120bpm

Tinsp                0.1~10.0s

I:E                   4:1~1:10

Pause                0~50%

PEEP                 0~50cmH2O

Pressure Support       0~80cmH2O

Pressure Control       5~80cmH2O

Fsens                0.5 ~ 20L/min.

Psens                0~20cmH2O below PEEP

Tslope               0~2s

Esens                5~80%

Phigh                5~80cmH2O

Plow                 0~50cmH2O

Thigh                0.2~30s

Tlow                 0.2~30s

Flow pattern          Square or descending

Monitoring

VTI                 0~4000mL

VTE                 0~4000mL

MV exp              0~99L

MV spn              0~99L

Ftotal               0~120bpm

Fspn                0~120bpm

I:E                  9:1~ 1:99

Ppeak               0~100cmH2O

Pmean              0~100cmH2O

PEEP                0~100cmH2O

Pplat                0~100cmH2O

Pmin               -20~100cmH2O

FiO2                15~100%

Cst                 0~300ml/cmH2O

Cdyn                0~300ml/cmH2O

Rst                 0~200cmH2O/L/S

RSBI                0~9999 bpm /L

PEEPi               0~100cmH2O

Alarms

Minute Volume

Low Limit Range        0~98L

High Limit Range        1~99L

Airway Pressure

Low Limit Range        0~98cmH2O

High Limit Range        6~99cmH2O

FiO2

Low Limit Range        18~99%

High Limit Range        19~100%, OFF

Expiratory Tidal Volume

Low Limit Range         OFF, 10 ~ 2990ml

High Limit Range        20~3000ml

Breath Rate

Low Limit Range         0 ~ 99bpm

High Limit Range        1 ~ 100bpm

Apnea Time

High Limit Range         10 ~ 60s

Display Specifications

Screen Size             12.1 inch TFT

Touch screen Type       Resistance

Waveforms             P-T,F-T and V-T

Loops                 P-V,P-F and F-V

Electrical Specifications

Power

Mains Power Supply      100~240VAC  50/60Hz

Current Input            1A max

Power Consumption      Appox. 65VA

Backup Battery

Battery Type             Li-ion Battery

Operating time           More than 3 hours

Charge time             4 hours max

Pneumatic Specifications

Gas Type                Oxygen and Medical Air

Gas Supply Requirement    280 ~ 600kPa

Related Products

SMT-30F Medical Ventilator

High-flow nasal cannula SMT-30F is a High Flow Nasal Cannula Oxygen Therapy Device capable of delivering up to 100% humidified and heated oxygen at a flow rate of up to 80L/min, it delivers a mixed oxygen with an easy controlled temperature and humidity. The oxygen supply system provides a great solution of airway management and oxygenation improvement.